Home home Products product Vacuum Repair Parts product inficon Labcom Ion Source Series – Ion Source Filament Replacement for High-Performance Applications

inficon Labcom Ion Source Series – Ion Source Filament Replacement for High-Performance Applications

The inficon Labcom Ion Source Series provides high-performance ion sources equipped with replaceable filaments. These ion sources are used across a wide range of applications, from scientific research to industrial analysis. With a focus on precision and reliability, the series ensures optimal ionization performance and extends the lifespan of your equipment. Learn how to efficiently replace or repair the ion source filament to keep your systems running smoothly.

Contact us

 inficon Labcom Ion Source Series – Ion Source Filament Replacement for High-Performance Applications

The inficon Labcom Ion Source Series offers advanced ion source solutions for high-performance applications. With efficient filament replacement and repair services, these ion sources are ideal for scientific research, analytical instruments, and industrial applications. Enhance the performance and longevity of your equipment with Infucon Labcom.

 inficon Labcom Ion Source Series – Technical Specifications for Reliable Performance

Parameter Description
Model inficon Labcom Ion Source Series
Filament Type Replaceable Filament (Specific models available)
Ionization Mode Electron Impact Ionization (EI) or Chemical Ionization (CI)
Filament Life Up to 500 hours of continuous use (varies by model)
Voltage Range 0-30 kV
Current Range 10-100 µA
Power Supply Compatibility Compatible with standard ion source power supplies
Filament Material Tungsten or Molybdenum
Temperature Range 500-3000 °C
Weight Varies by model (typically 0.5-2 kg)
Dimensions Varies by model, compact design

 Key Advantages of the inficon Labcom Ion Source Series for High-Performance Applications

1. High Precision Ionization

The inficon Labcom Ion Source Series offers superior precision in ionization, making it ideal for analytical equipment such as mass spectrometers and gas chromatographs. The replaceable filament technology ensures that your ionization source maintains consistent and reliable performance.

2. Long Service Life and Filament Replacement

With a filament lifespan of up to 500 hours (depending on the model and usage), the inficon Labcom Ion Source reduces downtime. When the filament needs replacement, it is a straightforward process, keeping your equipment up and running with minimal maintenance costs.

3. Versatile and Adaptable

Whether you need Electron Impact Ionization (EI) or Chemical Ionization (CI), the inficon Labcom Ion Source Series is compatible with both modes, offering flexibility for various research and industrial applications.

4. Energy Efficiency

The Ion Source Series is designed to maximize energy efficiency, ensuring low power consumption without sacrificing performance. This is especially important in research labs and industrial settings, where cost and energy savings are essential.

5. Compatibility with Major Equipment

These ion sources are compatible with a wide range of mass spectrometers, gas chromatographs, and other analytical instruments, providing a seamless experience for users across various scientific and industrial applications.


 Applications of the inficon Labcom Ion Source Series

The inficon Labcom Ion Source Series serves a variety of high-performance applications, including:

  • Mass Spectrometry: Crucial for obtaining accurate molecular weights and structures in both organic and inorganic analyses.
  • Gas Chromatography (GC): Ideal for providing consistent ionization in GC instruments, ensuring precise analysis of gases and volatile compounds.
  • Environmental Testing: Used for detecting trace elements and pollutants in air, water, and soil.
  • Chemical Research: Facilitates advanced chemical analysis and research, providing precise ionization for identifying and quantifying compounds.
  • Industrial Applications: Employed in the analysis of chemical products, petrochemicals, and materials, helping improve production quality and process efficiency.

 How to Replace the Ion Source Filament in the inficon Labcom Series

  1. Power Down the Equipment: Always ensure that the power to your equipment is off before beginning any maintenance procedure.
  2. Access the Ion Source: Depending on the model, the ion source can typically be accessed by removing a protective cover or housing.
  3. Remove the Old Filament: Gently remove the filament by releasing the securing clips or screws that hold it in place. Be cautious not to damage any surrounding components.
  4. Install the New Filament: Carefully insert the new filament, ensuring it is properly aligned and securely fastened.
  5. Reconnect and Test: Once the new filament is in place, reassemble the housing and power up the equipment. Test the ionization performance to ensure everything is functioning correctly.

Installation Process for inficon Labcom Ion Source Series

  1. Position the Ion Source: Install the inficon Labcom Ion Source into the appropriate chamber or interface of your analytical equipment. Ensure proper alignment with the ionization chamber for optimal performance.
  2. Connect to Power Supply: Ensure that the ion source is connected to the power supply with the appropriate voltage and current specifications.
  3. Check for Compatibility: Confirm that the ion source is compatible with the specific instrument you are using, including any necessary adapters for proper installation.
  4. Test Functionality: Power up the equipment and conduct a short test to confirm that the ionization is functioning as expected.

Frequently Asked Questions (FAQs) about the inficon Labcom Ion Source Series

  1. How do I replace the filament in the inficon Labcom Ion Source Series?
    Replacing the filament is simple. Power down your equipment, remove the old filament, and install the new one securely. Follow the instructions in the user manual for your specific model.

  2. What is the lifespan of the ion source filament?
    The filament can last up to 500 hours of continuous use, depending on the specific model and operating conditions.

  3. Which gases can be ionized with the inficon Labcom Ion Source?
    The inficon Labcom Ion Source is compatible with a variety of gases, including but not limited to, hydrogen, nitrogen, and noble gases, which are commonly used in mass spectrometry and chromatography.

  4. What types of ionization modes are supported by the inficon Labcom Ion Source?
    The inficon Labcom Ion Source supports both Electron Impact Ionization (EI) and Chemical Ionization (CI) modes, making it adaptable for different analysis needs.

  5. Can I use the inficon Labcom Ion Source with all mass spectrometers?
    Yes, the inficon Labcom Ion Source is compatible with most major brands and models of mass spectrometers and other analytical equipment.

  6. Is the Ion Source Series energy-efficient?
    Yes, the inficon Labcom Ion Source Series is designed with energy efficiency in mind, helping reduce power consumption without sacrificing performance.

  7. How do I install the Ion Source in my analytical equipment?
    The ion source is installed by carefully positioning it in the ionization chamber and connecting it to the power supply. Follow the manufacturer’s installation guide for detailed steps.

  8. What maintenance is required for the Ion Source?
    Regular maintenance includes checking the filament, replacing it when necessary, and ensuring that the ionization chamber is clean and free from contamination.

  9. Are calibration services available for the Ion Source?
    Yes, calibration services are available to ensure that your Ion Source is performing within specifications. Contact our service department for more information.

  10. What industries can benefit from using the inficon Labcom Ion Source?
    The inficon Labcom Ion Source is ideal for use in scientific research, environmental testing, chemical manufacturing, and any industry that requires high-performance ionization for analysis.